Hello,
After 6 hours of trials I have no more solution to make my Weste Digital HDD operating again.
Problem:
I share a NTFS WD HDD with my wife who is ruing under Windows. She used it a lot recently with my ubuntu to backup all her pictures.
It leads to have HDD no more operational under its windows (it blocks Windows computers after mounting) but it was still operation under my ubuntu.
Ubuntu version:
Code:
cedric@laptop-cedric:~$ uname -a Linux laptop-cedric 4.2.0-30-generic #36-Ubuntu SMP Fri Feb 26 00:57:19 UTC 2016 i686 i686 i686 GNU/Linux
HDD Hardware Version:
Code:
cedric@laptop-cedric:~$ sudo lsusb Bus 002 Device 008: ID 1058:0740 Weste Digital Technologies, Inc. My Passport Essential (WDBACY)
I tried to use also testdisk or Photorec but the disk is no more detected...
Error message from the disk:
Code:
cedric@laptop-cedric:~$ dmesg | tail -n 30 [19052.828026] sd 10:0:0:0: [sdb] Sense Key : Not Ready [current] [19052.828029] sd 10:0:0:0: [sdb] Add. Sense: Logical unit is in process of becoming ready [19054.847965] sd 10:0:0:0: [sdb] Test WP failed, assume Write Enabled [19056.867921] sd 10:0:0:0: [sdb] Asking for cache data failed [19056.867927] sd 10:0:0:0: [sdb] Assuming drive cache: write through [19056.875402] sd 10:0:0:0: [sdb] Spiing up disk... [19059.888204] ......................................................................not responding... [19309.365709] sd 10:0:0:0: timing out command, waited 180s [19489.369634] sd 10:0:0:0: timing out command, waited 180s [19669.377830] sd 10:0:0:0: timing out command, waited 180s [19669.377855] sd 10:0:0:0: [sdb] Read Capacity(10) failed: Result: hostbyte=DID_OK driverbyte=DRIVER_SENSE [19669.377859] sd 10:0:0:0: [sdb] Sense Key : Hardware Error [current] [19669.377863] sd 10:0:0:0: [sdb] Add. Sense: Inteal target failure [19669.379084] sd 10:0:0:0: [sdb] Unit Not Ready [19669.379086] sd 10:0:0:0: [sdb] Sense Key : Hardware Error [current] [19669.379089] sd 10:0:0:0: [sdb] Add. Sense: Inteal target failure [19849.381646] sd 10:0:0:0: timing out command, waited 180s [19849.383287] sd 10:0:0:0: timing out command, waited 180s [20029.389590] sd 10:0:0:0: timing out command, waited 180s [20029.389614] sd 10:0:0:0: [sdb] Attached SCSI disk [20029.391226] sd 10:0:0:0: timing out command, waited 180s [20209.393693] sd 10:0:0:0: timing out command, waited 180s [20209.393770] sd 10:0:0:0: [sdb] Read Capacity(10) failed: Result: hostbyte=DID_OK driverbyte=DRIVER_SENSE [20209.393783] sd 10:0:0:0: [sdb] Sense Key : Hardware Error [current] [20209.393793] sd 10:0:0:0: [sdb] Add. Sense: Inteal target failure [20389.397739] sd 10:0:0:0: timing out command, waited 180s [20569.405651] sd 10:0:0:0: timing out command, waited 180s [20569.411013] sd 10:0:0:0: [sdb] Unit Not Ready [20569.411018] sd 10:0:0:0: [sdb] Sense Key : Hardware Error [current] [20569.411021] sd 10:0:0:0: [sdb] Add. Sense: Inteal target failure


Thanks for your support as I have no more solution from my side...